The units remove salts from seawater with salinity up to 45,000 ppm TDS water as found globally and produce water less than 500 ppm TDS for drinking water. Our high purity line of products can also purify seawater down to less than 10 ppm TDS water for boiler feed and other high purity applications.
Typical System Features:
Multimedia Filter :
Multimedia filter is Fiberglass tank prefilter with manual backwash valve to remove particles to 25 micron (option - automatic backwash valve)
Prefiltration :
20 & 5 micron cartridge prefilter to remove particulate matter (1 micron available)
Filter housing design for easy filter changes.
Booster Pump :
Stainless steel booster pump of centrifugal design.
Ensures positive water pressure to unit.
Close coupled to TEFC (Totally Enclosed, Fan-Cooled) motor to withstand saltwater environment.
High Pressure Pump :
High pressure pump driven by TEFC motor.
Pulsation dampener to extend life, reduce noise & vibration.
Reverse Osmosis Membrane - Pressure Vessel Assembly:
Spiral wound, polyamide, thin film composite reverse osmosis membrane representing state of the art technology.
High water purity with membrane rejection of 99.6%
Membrane is designed for long life with easy cleaning.
Membrane is enclosed in fiberglass pressure vessel with ratings to 1000 psi.
Easy to change and plug assembly with long life and durability.
Premium quality high pressure fittings.
High pressure components rated at 2 times maximum operating pressure for safety.
Membrane isolation manifold for sampling each membrane product water individually (optional).
Instrumentation & Protective Features:
PLC base panel to controlled all instrumentation & operation.
Digital salinity controller with readout for temperature and salinity.
Easy to read gauges including product flowmeter and low and high pressure gauges.
Start/Stop switch with built in motor overload protectors.
Totalizing hour meter.
High pressure regulating valve.
Premium quality high pressure fittings.
Electronic salinity controller to automatically direct product water to waste when potable by means of a 3-way actuated valve.
High quality water indicator lights.
All water tight electrical connections.
Splash resistant electrical enclosures (Nema 4 or 12).
Brine check valve ensures only first quality water to storage tank.
Glycerin filled 316 SS high and low pressure gauge for long life.
Frame :
Epoxy coated frame for lifetime of service and corrosion resistance.
Open frame design for easy maintenance.
Unitized in integrated components for easy maintenance.
Secure mounting tabs/holes for stability.
Connections:
Food grade tubing for contact with potable water.
Stainless fasteners resist corrosion.
Membrane Care:
Automatic Backflush Systems to supply fresh water to membranes upon shutdown.
Membrane cleaning system valving and controls to facilitate chemical cleaning of membranes.
Automation:
Automated control system based on a in built programmable logic controller (PLC)
Automated start up operation activated by selector switch Auto/manual switch.
Self diagnostic built-in-test equipment with automatic fail safe for various conditions status display on front display panel.
Emergency stop
The containerized water treatment plant is a fully automated sea water desalination plant and designed to provide coastal camps, vacation units small settlements and military units with fresh drinking water.
Priciple:reverse osmosis
The plant shall be designed to be easy to put into operation withoutcomplex installation or civil works. The complete system, including piping, heating, ventilation and generator.The sea water desalination plant is built into a 20’ ISO-container
Operating principle Specifications:
Raw water pumping
Pre-filtration of sea-water
Reverse osmosis desalination
Chlorination of the treated water
Storage in buffer tank
Applications:
Private and municipal supply, military use
Raw water:
Sea water, well water, brackish water
Capacity:
30,000 l drinking water per day
Scope of supply:
20 feet container
generator
heating system, ventilation
raw water intake system
pre-filtration
reverse osmosis unit
dosing station chlorine
buffer tank
Optional equipment:
Potable water tank, dispenser
Reverse osmosis (RO) is a membrane-technology filtration method that removes many types of large molecules and ions from solutions by applying pressure to the solution, when it is on one side of a selective membrane. The result is that the solute is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the other side. To be "selective," this membrane should not allow large molecules or ions through the pores (holes), but should allow smaller components of the solution (such as the solvent) to pass freely. Reverse osmosis is used to purify Water and remove salts and other impurities in order to improve the color, taste or properties of the fluid.
Principle :
Osmosis is a natural process. When two liquids of different concentration are separated by a semi permeable membrane, the fluid has a tendency to move from low to high solute concentrations for chemical potential equilibrium.
Osmosis describes how solvent moves between two solutions separated by a permeable membrane to reduce concentration differences between the solutions. When two solutions with different concentrations of a solute are mixed, the total amount of solutes in the two solutions will be equally distributed in the total amount of solvent from the two solutions. Instead of mixing the two solutions together, they can be put in two compartments where they are separated from each other by a semipermeable membrane. The semi permeable membrane does not allow the solutes to move from one compartment to the other, but allows the solvent to move.
Formally, reverse osmosis is the process of forcing a solvent from a region of high solute concentration through a semipermeable membrane to a region of low solute concentration by applying a pressure in excess of the osmotic pressure. The membranes used for reverse osmosis have a dense layer in the polymer matrix where most separation occurs.
Advantages :
Our Reverse Osmosis Plant have the following Advantages :
Actively rejects ions and contaminants.
Reduce Water that meets the most demanding specifications.
Allow the membrane to continually clean itself
Higher pressure from the pump to push the fluid through the membrane.
Capable of rejecting bacteria, salts, sugars, proteins, particles, dyes and other constituents.
Works in various molecular weights.
Applications :
Drinking Water purification
Water and wasteWater purification
Food industry
Car washing
Hydrogen production
Reef aquariums
Drinking Water purification:
Around the world, household drinking Water purification systems, including a reverse osmosis step, are commonly used for improving Water for drinking and cooking.
Water and wasteWater purification:
Rain Water collected from storm drains is purified with reverse osmosis Water processors and used for landscape irrigation and industrial cooling, as a solution to the problem of Water shortages.
Food industry :
In addition to desalination, reverse osmosis is a more economical operation for concentrating food liquids (such as fruit juices) than conventional heat-treatment processes. Research has been done on concentration of orange juice and tomato juice. Its advantages include a lower operating cost and the ability to avoid heat-treatment processes, which makes it suitable for heat-sensitive substances like the protein and enzymes found in most food products.
Car washing :
Because of its lower mineral content, reverse osmosis Water is often used in car washes during the final vehicle rinse to prevent Water spotting on the vehicle. Reverse osmosis is often used to conserve and recycle Water within the wash/pre-rinse cycles, especially in drought stricken areas where Water conservation is important. Reverse osmosis Water also enables the car wash operator to reduce the demands on the vehicle drying equipment, such as air blowers.
Hydrogen production :
For small scale production of hydrogen, reverse osmosis is sometimes used to prevent formation of minerals on the surface of electrodes.
Reef aquariums :
Many reef aquarium keepers use reverse osmosis systems for their artificial mixture of seaWater. Ordinary tap Water can often contain excessive chlorine, chloramines, copper, nitrogen, phosphates, silicates, or many other chemicals detrimental to the sensitive organisms in a reef environment. Contaminants such as nitrogen compounds and phosphates can lead to excessive, and unwanted, algae growth. An effective combination of both reverse osmosis and deionization (RO/DI) is the most popular among reef aquarium keepers.
We Offer :
A] We offer extremely reliable and simplified range of Customized RO UF Plants. Being user-friendly and aesthetically excellent, these RO & UF Plants have become one of the coveted choices available in the market.
These are designed in capacities ranging between 200 lph and 50000 lph and ever more to suffice to the discerning needs. The well designed pretreatment and PLC/Controller based automation are done as per specific requirements. These are available in ‘Economy’ and ‘Premium’ versions.
B] Cabinet Type : RO/ UF
We offer fully automatic Cabinet Type RO filtration plants. These are devised and Packaged in large standardized containers making them compact and aesthetically superior.
The precision equipment and other component part are enclosed in MS powder-coated box. The typical capacities of our Cabinet Type RO UF are 50, 100, 200, 500 & 1000 lph. These can also be configured in small capacities benefiting the client's requirements.